OM-196 188 Page 107
SECTION 14 – SETUP
14-1. Setup Flow Chart
>Memory No Reset No Reset 14-12
Program
Reset
System
Reset
Total
Reset
>Wiretype Wire Type Hardwire/ Hardwire 14-10
Softwire
>Arc Start Arc Start Standard Standard 14-7
Type Hot Start
Soft Start
>Monitor Arc Volts Off/On Off 14-19
Range 0.1 - 9.9 2.0 Volts
Sec 0.1 - 25 1.0 Sec.
>Program Remote Off/On Off 14-15
Select
>Shutdown Arc Start/ Off/On On 14-13
Volt Sense
>Access Code Off/On Off 14-3
Display Features Settings Default Section
Selection
>Mig Type Voltage DVC On/Off Off 14-4
Correction
>Voltage Control Internal Internal 14-6
Feedback Volt Sense
>Arc Time Run Hours 0–9999.99 14-8
Hours
0–999,999
Cycles
No Reset No Reset
Reset
1 Display Selections
2 Features
3 Settings
To set up features that customize operation, use the setup
displays. Features that can be customized are as follows:
Access
Mig Type
Aux Out
Voltage
> Volt Min
10.0 Volt
1
Display Features Settings Default Section
Selection
>Name Card Off/On On 14-14
Programs
>Wire Feed Display IPM/MPM IPM 14-9
Motor Type Standard Standard
Low Speed
High Speed
Press Mode Select To
Go To Next Setup Dis-
play
>Aux Output Auxiliary Output On Never 14-5
Output w/Feeder
w/Arc
w/Weld Cycle
Never
>Stick Stick Check Off/On Off 14-20
>Jog IPM Robot Jog Remote/Local Local
Local Jog
IPM 50 - 780 200 14-17
2
3
Example Setup
Pendant Display
>Flow Detect Flow Off/On Off 14-18
>Display Actual Command 14-11
Amps
Command
>Ramps Program Number 1 14-21
Start Off/On Off
Crater Off/On Off
>Exit Exit Setup Press
Menu Now 14-23
>Software Version 14-22
Number