Pulse
035” Steel
Argon – Oxy
> Teach Off
When the Process Teach mode is On, and
one of the following pulse parameters is se-
lected: Apk, Abk, PPS, PWms, or Vpk, the
pulse panel displays the selected pulse pa-
rameter instead of Trim (arc length). When
the pulse parameter is selected, the value
can be changed with the pulse panel controls
as follows:
1 Vpk Display
2 Apk Display
3 Abk Display
4 PPS Display
5 PWms Display
When values have been set for a teach point,
strike and maintain an arc for five seconds.
Repeat procedure at each teach point until
custom program is complete (see Section
10-2).
Turn Teach mode Off.
6 Custom Pulse Screen
The letter C will appear in the upper right
corner of all customized programs.
Customized programs can be reverted back
to factory-set values through memory reset
(see Section 14-12).
> Process
Sequence
SharpArc
Card
1
Prg 1 C
Pulse
035” Steel
Argon – Oxy
3
> Teach On
450 IPM
31.2 Vpk
343 Apk
Teach On
450 IPM
> 28.1 Vpk
340 Apk
Teach On
> 450 IPM
28.1 Vpk
340 Apk
2
4
6
10-4. Setting Teach Point Parameters For Pulse Welding Program
Parameter
Select
Increase/
Decrease
Or
Parameter
Select
Increase/
Decrease
Parameter
Select
Increase/
Decrease
Parameter
Select
Increase/
Decrease
Wait for 5
seconds
Parameter
Select
Increase/
Decrease
Parameter
Select
Parameter
Select
Increase/
Decrease
343 Apk
92 Abk
280 PPS
> 1.9 PWms
343 Apk
92 Abk
280 PPS
> 3.6 PWms
5
Teach On
450 IPM
> 31.2 Vpk
340 Apk
450 IPM
31.2 Vpk
> 340 Apk
70 Abk
450 IPM
31.2 Vpk
> 343 Apk
70 Abk
31.2 Vpk
343 Apk
>70 Abk
160 PPS
31.2 Vpk
343 Apk
>92 Abk
160 PPS
31.2 Vpk
343 Apk
92 Abk
> 160 PPS
31.2 Vpk
343 Apk
92 Abk
> 280 PPS