Miller Electric Welder Welding System User Manual


 
OM-196 188 Page 88
SECTION 9 – GETTING STARTED FOR PULSE WELDING
Ref. S-0271
9-1. Weld Cycle For Pulse Welding
Wire
Speed
Weld
Start
Start
Power
Start
Speed
Preflow
Time
Arc
Strike
Weld
Speed
Weld Time
Weld
Stop
Crater Time
Crater
Speed
Arc
Out
Retract Time
Postflow
Time
TimeRun-In
Setting
Robot
Motion
. The type of robot connected determines what
combination of parameters are available.
Run-In
WFS
9-2. Setting Preflow Sequence Display
1 Mode Select Button
When unit is turned On, Process is
the default mode, at other times,
use mode select button to select
Sequence.
2 Parameter Select Button
Use parameter select button to
select parameters.
3 Preflow Parameters Display
Preflow can be adjusted from 0-9.9
seconds. If value set is zero (0),
there is no Preflow sequence.
Go to Section 9-3.
3
> Prflw
0.0 Sec
Prflw
> 0.0 Sec
> Prflw
1.2 Sec
2
Process
> Sequence
SharpArc
Card
> Prflw
0.0 Sec
1
Mode Select Parameter
Select
Parameter
Select
Parameter
Select
Set Desired Time
Increase/
Decrease
Increase
Proceed to next Section.