Miller Electric Welder Welding System User Manual


 
OM-196 188 Page 89
9-3. Setting Weld Sequence Display
1 Weld Parameters Display
Parameter ranges are as follows:
Trim (Arc Length), 0-99
Wire Feed Speed, 50-780 Inches
Per Minute, IPM
Go to Section 9-4.
Weld
60 Trim
> 200 IPM
> Weld
60 Trim
300 IPM
1
Weld
>50 Trim
200 IPM
Increase/
Decrease
Set Desired Weld
Sequence Trim
Parameter
Select
Set Desired Weld Sequence
Wire Feed Speed
Increase/
Decrease
Parameter
Select
Increase
Proceed to next Section.
9-4. Setting Crater Sequence Display
1 Crater Parameters Display
Parameter ranges are as follows:
Seconds, 0-2.50 Sec. If value set is
zero (0), there is no Crater
sequence.
Trim (Arc Length), 0-99
Wire Feed Speed, 50-780 Inches
Per Minute, IPM
Go to Section 9-5.
1
>Cratr
0.00 Sec
50 Trim
200 IPM
Cratr
0.20 Sec
>50 Trim
200 IPM
Cratr
0.20 Sec
60 Trim
> 150 IPM
Cratr
> 0.00 Sec
50 Trim
200 IPM
> Cratr
0.20 Sec
60 Trim
150 IPM
Parameter
Select
Set Desired
Time
Parameter
Select
Increase/
Decrease
Increase/
Decrease
Increase/
Decrease
Parameter
Select
Parameter
Select
Increase
Proceed to next Section.
Set Desired Wire
Feed Speed
Set Desired
Trim