Miller Electric Welder Welding System User Manual


 
OM-196 188 Page 92
10-3. Selecting Teach Point Wire Feed Speed For Pulse Welding Program
1 Process Display
When unit is first turned On,
Process is the default screen, at
other times use mode select button
to select Process.
2 Teach Display
Use parameter select button to
select Teach.
Use increase/decrease buttons to
select On.
3 IPM (Teach Point)
The parameters associated with
this wire feed speed teach point can
be modified. The wire feed speed
value itself cannot be changed from
the set point.
To set or adjust teach point parame-
ters, go to Section 10-4.
3
1
> Process
Sequence
SharpArc
Card
> Prg 1
Pulse
035” Steel
Argon – Oxy
Pulse
035” Steel
> Teach Off
Teach On
> 400 IPM
28.1 Vpk
340 Apk
> Teach On
400 IPM
28.1 Vpk
340 Apk
2
Mode
Select
Parameter
Select
Parameter
Select
Increase/
Decrease