Miller Electric Welder Welding System User Manual


 
OM-196 188 Page 98
1 Crater Parameters Display
Parameter ranges are as follows:
Seconds, 0-2.50 Sec. If value set is
zero (0), there is no Crater
sequence.
Volts, 10.0-38.0 Volts.
Wire Feed Speed, 50 to 780 inches
per minute, IPM.
Go to Section 11-7.
> Cratr
0.02 Sec
24.0 Volt
90 IPM
Cratr
0.12 Sec
> 18.0 Volt
90 IPM
Cratr
0.12 Sec
18.0 Volt
> 200 IPM
Cratr
> 0.12 Sec
24.0 Volt
90 IPM
> Cratr
0.12 Sec
18.0 Volt
200 IPM
1
11-6. Setting Crater Sequence Display
Set Desired Time
Parameter
Select
Increase/
Decrease
Increase
Proceed to next Section.
Parameter
Select
Parameter
Select
Set Desired
Voltage
Increase/
Decrease
Parameter
Select
Set Desired Wire
Feed Speed
Increase/
Decrease
1 Retract Parameter Display
Parameter range is as follows:
Seconds, 0-1.00 seconds. If value
set is zero (0), there is no Burnback
sequence.
IPM 50-780 (1.3-19.8 mpm). Speed
is program dependent.
Go to Section 11-8.
1
> Rtrct
150 IPM
0.00 Sec
Rtrct
> 150 IPM
0.00 Sec
Rtrct
120 IPM
> 0.00 Sec
11-7. Setting Retract Sequence Display
Set Desired Speed
Parameter
Select
Parameter
Select
Increase/
Decrease
> Rtrct
130 IPM
0.12 Sec
Parameter
Select
Increase
Proceed to next Section.
Set Desired Time
Increase/