Miller Electric Welder Welding System User Manual


 
OM-196 188 Page 112
1 Wire Feed Display
The displayed unit of wire speed
(IPM or MPM) can be changed
along with the wire feed motor type
(Standard, Low Speed, or High
Speed).
ArcStart
Arc Time
> Wirefeed
Wiretype
Display
> IPM
Motor Type
Standard
Display
> MPM
Motor Type
Standard
1
Display
IPM
Motor Type
> Standard
Display
IPM
Motor Type
> Low Spd
Display
IPM
Motor Type
> High Spd
14-9. Selecting Units For Wire Feed Speed And Motor Type
Press Mode
Select
Parameter
Select
Increase
Access
Setup
Display
Increase
Decrease
Increase