Miller Electric Welder Welding System User Manual


 
OM-196 188 Page 116
1 Jog IPM Display
Jog wire feed speed can be varied
between 50 and 780 inches per
minute, IPM.
When not welding, a Robot Jog
local setting will jog wire at the Local
Jog ipm setting, even if robot pro-
vides wire jog signal.
A Robot Jog remote setting
requires that the robot provide a jog
command and jog speed signal.
Auxiliary jog connections at the
peripheral receptacle and front
panel jog push buttons will jog wire
at the Local Jog ipm setting even if
Robot Jog is set for remote.
Name
Program
> Jog IPM
Flow
Robot Jog
> Remote
Local Jog
200 ipm
1
14-17. Jog Wire Feed Speed Selection
Press Mode
Select
Increase
Access
Setup
Display
Robot Jog
> local
Local Jog
200 ipm
Parameter
Select
Robot Jog
local
Local Jog
> 200 ipm
Increase/
Decrease
Robot Jog
local
Local Jog
> 425 ipm
Parameter
Select
1 Flow Display
Provides a means to
enable/disable the flow switch
input.
When this feature is off, no
monitoring is done for a flow switch
input signal.
When this feature is on, the flow
detect input monitors flow switch
signal and will cause an error if flow
is not present.
Program
Jog IPM
> Flow
Monitor
Detect
Flow
>Off
Detect
Flow
>On
1
. When a system reset is
done, Flow is set to Off.
14-18. Flow Selection
Press Mode
Select
Increase
Access
Setup
Display