OM-196 188 Page 122
15-5. Setting Retract On/Off
1 Retract Display
Settings allow user to turn the re-
tract feature On or Off. The retract
feature allows the user to set a time
and wire feed speed to pull wire
away from work when the weld is
done.
Use Increase or Decrease button to
change setting. If the retract feature
is turned On, a weld sequence step
is added in the process screens.
Press Mode Select button to go to
next parameter or cycle power off
and back on at power switch to sav-
e setting and exit Control menu.
1
Access
Control
Display
Increase/
Decrease
>Process
Sequence
SharpArc
Card
> Prg 1
Pulse
035” Steel
Argon – Oxy
Adaptive
AutoConfig
> Retract
ShrpStrt
> Retract
On
Mode
Select
Or
> Retract
Off
Go To
Section 15-6
Power
Switch
Press Mode
Select
15-6. Setting Sharp Start On/Off
1 Sharp Start Display
Settings allow user to turn the sharp
start feature On or Off.
. Sharp start should normally be
left On. The ability to turn sharp
start Off is provided in case the
user experiences problems
with weld ends using flux cored
wires.
Use Increase or Decrease button to
change setting.
Press Mode Select button to go to
next parameter or cycle power off
and back on at power switch to sav-
e setting and exit Control menu.
1
Access
Control
Display
Increase/
Decrease
>Process
Sequence
SharpArc
Card
> Prg 1
Pulse
035” Steel
Argon – Oxy
AutoConfig
Retract
> ShrpStrt
Exit
> ShrpStrt
On
Mode
Select
Or
> ShrpStrt
Off
Go To
Section 15-4
Power
Switch
Press Mode
Select