Baldor MN735 Welding System User Manual


 
Receiving & Installation 311MN735
External Brake Resistor
Connect the dynamic brake resistor between terminals DC+ and DBR as
shown in Figure 3-5 and 3-6.
User Relay A customer provided, external DC or AC power supply must be used
if relay output is to be used.
RL1A
Load
Customer Provided Load
Volts
RL1B
Control
Note: Contact is rated to 250V @ 4A
resistive (noninductive).
Contact is open
when power is on
and no faults are
present.
Applications/Modes There are 6 operating modes. Each mode configures the
terminal strip wiring for a specific application. The following diagrams
document the terminal strip wiring for each (Application 0 to Application 5).
Note: Parameter values are not changed by loading a new Application.
How to Load an Application
In the
menu, go to and press the key.
The Applications are stored in this menu.
Use the
keys to select the appropriate Application by number.
Press the
key to load the Application.