Baldor MN735 Welding System User Manual


 
StartUp and Operation 49MN735
Table 4-1 Parameter Definitions Continued
Display Parameter Description Range Factory
Setting
SET::IN Menu Continued
DIN 1 VALUE
~
The input signal after inversion (if any). 0= False
1= True
0
DIN 2 VALUE
~
The input signal after inversion (if any). 0= False
1= True
0
DIN 3 VALUE
~
The input signal after inversion (if any). 0= False
1= True
0
DIN 4 VALUE
~
The input signal after inversion (if any). 0= False
1= True
0
AIN 1 VALUE
~
The analog input signal with scaling and offset. x.x% x.x%
AIN 2 VALUE
~
The analog input signal with scaling and offset. x.x% x.x%
SET::OUT Menu
AOUT 1
SOURCE
ANALOG OUTPUT
0 NONE
1 DEMAND %
2 CURRENT %
3 PI ERROR %
4 RAISE/LOWER
Scale
Offset
Absolute
010V
OUTPUT%
0= NONE
1= DEMAND
2= CURRENT
3= PI ERROR
4= RAISE/LOWER
OUTPUT
1
AOUT 1 SCALE
Output
+
SCALE
OFFSET
X
Value
ABS
X
-300.0 to 300.0 100.0%
AOUT 1
OFFSET
-300.0 to 300.0% 0.00%
AOUT 1
ABSOLUTE
0= False
1= True
0
AOUT 1 VALUE
~
-300.0 to 300.0% 0.0%
DOUT 2
SOURCE
DIN4 / DOUT2
Invert
Output
0 NONE
1 HEALTH
2 TRIPPED
3 RUNNING
4 AT ZERO
5 AT SPEED
6 AT LOAD
0= NONE (DIN4)
1= HEALTH
2= TRIPPED
3= RUNNING
4= AT ZERO
5= AT SPEED
6= AT LOAD
0
DOUT 2
INVERT
(OUTPUT) As
S
IP01. Set to 0 for applications
1 & 5.
As
S
IP01 0
DOUT 2
VALUE ~
The output signal that represents the OP21
choice.
0= False
1= True
0
RELAY
SOURCE
RELAY
0 NONE
1 HEALTH
2 TRIPPED
3 RUNNING
4 AT ZERO
5 AT SPEED
Invert
Output
6 AT LOAD
0= NONE
1= HEALTH
2= TRIPPED
3= RUNNING
4= AT ZERO
5= AT SPEED
6= AT LOAD
2