Omron ZS-MDC Stud Sensor User Manual


 
Section 3 SETUP
Section 3
About Setup
3-7
ZS-MDC
User’s Manual
RUN Mode
In this mode, measured values are displayed on the main display, and threshold values
and other information are displayed on the sub-display.
Pressing the MENU key displays the display customize menu.
Details displayed on the sub-display
Key Operations
Display Details Description
THRESH Displays the HIGH/LOW threshold values according to the setting of the
threshold switch.
VOLTAGE (CURRENT) Displays the voltage (current) to be linearized. The display details change
according to the setting of the current/voltage switch. (Values displayed here
are reference values only. These values differ from actual linear output values.)
RESOLU Displays the fluctuation width (peak to peak) of the measured value over a
fixed amount of time.
DISTANCE Displays the measured value before it is processed by hold or other functions.
Key Measured Value Display Display Customize Menu
Function keys Not used Directly select functions.
LEFT key
RIGHT key
Changes sub-display content. The function changes depend-
ing on the settings.
• Scrolls pages in list menus.
• Selects digits.
Display customise menu
Measured value display
MAIN : MESURE
SUB : THRESH
MAIN : MESURE
SUB : VOLTAGE
MAIN : MESURE
SUB : DISTANCE
MAIN : MESURE
SUB : RESOLU
1DIGITAL
3HELP
2LCD