Omron ZS-MDC Stud Sensor User Manual


 
4-8
Section 4 APPLICATION SETTING EXAMPLES
ZS-MDC
User’s Manual
Section 4
Measuring the Reference Difference between Steps
Measuring the Reference Difference between Steps
This is an example of how to measure the height at three locations on a workpiece, and
calculate the difference (step difference) between the value of the reference height
(obtained by taking one of the locations to be the reference height) and the other two
locations. Use [STEP] (X-Y) for the expression.
For details on how to connect and install the Sensor Heads and Sensor Controllers, refer to the “ZS-L
User’s Manual.”
FUN Mode-[SENSING]-[SEL CH]
1. Assign the CH No. of the controller to inputs
A to C to be used for the expression.
INPUT A:1CH
INPUT B:2CH
INPUT C:3CH
Press MENU key - ESC key.
2. Select [TASK1].
Input A Input B Input C
Reference
difference
between steps
Reference
difference
between steps
CH0 CH1 CH2 CH3
Input A Input B Input C
The operation and/or measurement results are output
as judgement output or linear output.
1INPUT A
3INPUT C
2INPUT B
1TASK1
3TASK3
2TASK2
4TASK4