Section 4 APPLICATION SETTING EXAMPLES
Section 4
Measuring the Thickness of Multiple Points (sandwiched thickness)
4-3
ZS-MDC
User’s Manual
Press MENU key - ESC key.
2. Select [TASK1].
[SENSING]-[CALC]-[CALC]-[THICK]
3. Set the expression of TASK1.
INPUT X: INPUT A
INPUT Y: INPUT B
4. Place a workpiece of known thickness at the
rough sensor.
5. Select [THICK].
6. Enter the thickness of the workpiece.
The thickness of the workpiece you placed is
displayed on the LCD. Enter the thickness value
referring to the displayed value.
7. Press the SET Key to apply the setting.
8. Following the same procedure as 2 to 7, set
up TASK2 and TASK3.
(TASK2) Enter C to input X and D to input Y.
(TASK3) Enter E to input X and F to input Y.
▲
1TASK1
3TASK3
2TASK2
4TASK4
▲
1INPUT X
3THICK
2INPUT Y
Input A
Input B
X
Y
THICK : 0 1 0 . 0 0 0
DIG VAL
SETOK
THICK : 0 1 0 . 0 0 0
Complete!
Input C
Input D
Input E
Input F
X
Y