Omron ZS-MDC Stud Sensor User Manual


 
Section 4 APPLICATION SETTING EXAMPLES
Section 4
Measuring the Warp of a Workpiece
4-17
ZS-MDC
User’s Manual
Measuring the Warp of a Workpiece
In the example below, the difference between the points on both edges (input A point and
input C point) of the workpiece, the average distance value, and the measured value (input
B point) of the center is taken to be the warp amount. Expression: Z=B- (A+C)/2. In the
actual setting, calculation mode “K+mX+nY” is used.
For details on how to connect and install the Sensor Heads and Sensor Controllers, refer to the “ZS-L
User’s Manual”.
FUN Mode-[SENSING]-[SEL CH]
1. Assign the CH No. of the controller to inputs
A to C to be used for the expression.
INPUT A:1CH
INPUT B:2CH
INPUT C:3CH
Input A
Input B
Input C
CH0 CH1 CH2 CH3
Input A Input B Input C
The operation and/or measurement results are output
as judgement output or linear output.
1INPUT A
3INPUT C
2INPUT B