Setting I/O Assignments
Setting I/O Assignments
Switching banks by external signal input
Set the task or function to the external input.
If you use SmartMonitor Zero, you can change the function assignments of IN2 and IN3 if [BANK] is
selected. For details, refer to the Help for SmartMonitor Zero.
FUN mode-[I/O SET]-[I/O SET]-[IN]
For bank inputs A and B, the bank can be selected in the following combinations.
Bank switching is begun 0.5 seconds after the input state changes.
At most it takes about 10 seconds to switch banks.
During bank switching the BUSY output becomes ON.
Setting Description
TASK Select to task for enabling the external signal lead. Note, however, that reset input
and bank inputs affects tasks at all times.
Range: TASK1 to TASK4, TASK-ALL
FUNC NORMAL Select this to use external input function as in standard applications so far (default
value).
IN0 IN1 IN2 IN3
External trigger
(timing) input
Reset input Unused Zero reset input
BANK Select this to switch banks using external inputs.
IN0 IN1 IN2 IN3
Bank input A Bank input B Unused Zero reset input
Bank to be Selected Bank input A Bank input B
BANK1 OFF OFF
BANK2 OFF ON
BANK3 ON OFF
BANK4 ON ON