Omron ZS-MDC Stud Sensor User Manual


 
4-6
Section 4 APPLICATION SETTING EXAMPLES
ZS-MDC
User’s Manual
Section 4
Measuring the Relative Difference between Steps
[SENSING]-[CALC]-[CALC]-[STEP]
3. Set the expression of TASK1.
INPUT X: INPUT A
INPUT Y: INPUT B
4. Following the same procedure as 2 to 3, set
up TASK2.
INPUT X: INPUT B
INPUT Y: INPUT C
5. Following the same procedure as 2 to 3, set
up TASK3.
INPUT X: INPUT C
INPUT Y: INPUT A
• To output the judgment result of the operation
[I/O SET]-[I/O SET]-[OUT]
6. Select TASK1, TASK2, or TASK3 depending
on the details to be output.
To output judgment on the difference between
point A and point B: Set TASK1 to I/O SET
To output judgment on the difference between
point B and point C: Set TASK2 to I/O SET
To output judgment on the difference between
point C and point A: Set TASK3 to I/O SET
1INPUT X 2INPUT Y
Input A Input B Input C
Y X
Input A Input B Input C
X
Y
Input A
Input B
Input C
Y
X
1TASK1
3TASK3
2TASK2
4TASK4