Omron ZS-MDC Stud Sensor User Manual


 
3-14
Section 3 SETUP
ZS-MDC
User’s Manual
Section 3
Setting the Sensor Controller to Obtain Sensing Information from
Setting the Sensor Controller to Obtain Sensing Information from
Set which gang-mounted Sensor Controller to obtain information from, and which logic
operations are to be performed on that information.
Setting Assignments
Assign the channel to perform logic operation on.
FUNMode-[SENSING]-[SEL CH]
Setting Description
INPUT A (input A) Assigns the target Sensor Controller to input A.
Range: None, 1CH onwards (largest CH of gang-mounted Sensor Controllers)
(default: 1CH. Note that range becomes “None” if 1CH does not exist.)
INPUT B (input B) Assigns the target Sensor Controller to input B.
Range: None, 1CH onwards (largest CH of gang-mounted Sensor Controllers)
(default: 2CH. Note that range becomes “None” if 2CH does not exist.)
INPUT C (input C) Assigns the target Sensor Controller to input C.
Range: None, 1CH onwards (largest CH of gang-mounted Sensor Controllers)
(default: 3CH. Note that range becomes“None” if 3CH does not exist.)
INPUT D (input D) Assigns the target Sensor Controller to input D.
Range: None, 1CH onwards (largest CH of gang-mounted Sensor Controllers)
(default: 4CH. Note that range becomes “None” if 4CH does not exist.)
INPUT E (input E) Assigns the target Sensor Controller to input E.
Range: None, 1CH onwards (largest CH of gang-mounted Sensor Controllers)
(default: 5CH. Note that range becomes “None” if 5CH does not exist.)
INPUT F (input F) Assigns the target Sensor Controller to input F.
Range: None, 1CH onwards (largest CH of gang-mounted Sensor Controllers)
(default: 6CH. Note that range becomes “None” if 6CH does not exist.)
INPUT G (input G) Assigns the target Sensor Controller to input G.
Range: None, 1CH onwards (largest CH of gang-mounted Sensor Controllers)
(default: 7CH. Note that range becomes “None” if 7CH does not exist.)
INPUT H (input H) Assigns the target Sensor Controller to input H.
Range: None, 1CH onwards (largest CH of gang-mounted Sensor Controllers)
(default: 8CH. Note that range becomes “None” if 8CH does not exist.)
INPUT I (input I) Assigns the target Sensor Controller to input I.
Range: None, 1CH onwards (largest CH of gang-mounted Sensor Controllers)
(default: 9CH. Note that range becomes “None” if 9CH does not exist.)