Omron ZS-MDC Stud Sensor User Manual


 
Section 3 SETUP
Section 3
About Setup
3-9
ZS-MDC
User’s Manual
List of Setting Items
This manual describes only “FUN Mode-[SENSING]” functions unique to the Multi-Controller. Details of
other functions are the same as those for the Sensor Controller. Refer to the Sensor Controller Userís
Manual.
FUN Mode
This is the mode for setting the measurement conditions. The items that can be set dif-
fer according to which task is selected. When TASK1 is selected, all items including
items common to all tasks can be set. When a task other than TASK1 is selected, only
items specific to that task can be set.
When TASK1 is selected
Settings Default Value Option/Range
Pages
SENSING SEL CH
- Input A to input I p.3-14
CALC
CH OFF, CH (input A to input I), CALC
(THICK, STEP, K+mX+nY, AVE,
MAX-MIN)
p.3-15
FILTER SMOOTH
ON OFF, ON -
AVERAGE
1 1, 2, 4, 8, 16, 32, 64, 128, 256, 512,
1024, 2048, 4096
-
DIFF
OFF OFF, ON -
OUTPUT SCALING
OFF OFF, ON (AUTO, MAN) -
HOLD TYPE
OFF
OFF, PEAK, BOTTOM, P-P, AVERAGE,
SAMPLE
-
TRIGGER
EXT
EXT, SELF-UP, SELF-DN
-
DELAY
OFF OFF, ON (T-DELAY, T-TIME) -
0RESET TYPE
REAL REAL, HOLD -
OFFSET
0 -999.99 to 999.999 -
FUN Mode