Agilent Technologies E4446A Saw User Manual


 
Chapter 5 341
One-Button Measurement Functions
Mode Setup (Spectrum Analysis Mode)
One-Button Measurement Functions
5.3.2 Radio Std Setup
Accesses the key menu for selecting the device, packet type, or signal bandwidth to be
measured.
Key Path:
Mode Setup
History: Added with PSA firmware revision A.02.00
Remote Command:
There is no equivalent remote command.
5.3.2.1 Signal BW
Allows you to set the measurement bandwidth when
Radio Std (None) is selected. This
function is available only when you select None as the standard.
Key Path:
Mode Setup, Std Setup
Factory Preset: 3.0 MHz
Default Terminator: Hz
Range: The non-zero span range of the analyzer
History: Added with PSA firmware revision A.02.00
Remote Command:
[:SENSe]:RADio:STANdard:SBWidth <freq>
[:SENSe]:RADio:STANdard:SBWidth?
Example: RAD:STAN:SBW 2MHZ
5.3.2.2 Device BTS/MS
This function is only available when you have selected the standard: IS-95, J-STD-008,
cdma2000, W-CDMA, NADC, PDC, TETRA, or GSM. It enables you to select either the
base transmitter station (BTS) setup defaults or the mobile station (MS) defaults for the
standard that you have selected. This key is unavailable when you select Bluetooth™.
Key Path:
Mode Setup, Std Setup
Factory Preset: BTS
History: Added with PSA firmware revision A.02.00
Remote Command:
[:SENSe]:RADio:STANdard:DEVice BTS|MS
[:SENSe]:RADio:STANdard:DEVice?