GE GE752 Drill User Manual


 
Vertical Drilling Motor, Type GE752, GEK–91584D
47
62
1
VIEW AT A ENLARGED (TYPICAL)
ASSEMBLE FLUSH TO TOP OF INSIDE
WALL WITHIN .25 & TIGHEN UNTIL
PLUG IS EXPANDED & TIGHT IN HOLE
+
2,
3
15
16
9
2,3
17
17
VIEW AT B ENLARGED (TYPICAL)
41
42
42,44
SIDE VIEW OF COMM. CHAMBER
SHOWING PLUGS ON SIDE
OPPOSITE CONNECTION BOX.
42,44
P44 FOR PRESSURE SWITCH USAGE
ON CONNECTION BOX SIDE ONLY.
IF NO PRESSURE SWITCH IS
REQUIRED, PLUG HOLE WITH P42
SECTION C–C
CONN. BOX
GROUND ARMOR WITH P52
(G3 & G4 ONLY)
VIEW AT D
STAPLE
10
MAG. FRAME
WALL
SECTION E–E
ATTACH BRUSH HOLDER CABLES
AGAINST INSIDE WALL OF MAG. FRAME
38
34,
36
CARBON
BRUSH
37
VIEW SHOWING
BRUSH HOLDER ASSEMBLY
NOTE FOR P61: ATTACH MARKING BAND (P61) TO
EACH END OF CABLE PTS. 11,12,13,45,46,47,48,
50,56,57,58,64,65,67 & STAMP WITH APPROPRIATE
MARKINGS AT ASSEMBLY.
TORQUE TABLE
PART SIZE TORQUE LB.–FT.
32–74 1.25–7 900–1000
33 1.25–12 435–483
34 .875–9 115–125
LUBRICATE BOLTS
FIG. 29. COILED FRAME ASSEMBLY (41D732353 CHG. N). E–39094A.
MODELS
SEE TABLE 2, PAGE 20