HP (Hewlett-Packard) 53A Welder User Manual


 
:MONitor[:STATe] DISPlay:MONitor[:STATe] <mode> turns the monitor mode on or off.
Parameters
Parameter Name Parameter Type Range of Values
mode
Boolean 0 | 1 | ON | OFF
Comments Monitoring Switchbox Channels: DISPlay:MONitor[:STATe] ON
or DISPlay:MONitor[:STATe] 1 turns the monitor mode on to show
the channel state of the selected module.
DISPlay:MONitor[:STATe]
OFF
or DISPlay:MONitor[:STATe] 0 turns the monitor mode off.
Selecting the Module to be Monitored: Use the DISPlay
MONitor:CARD <
number> | AUTO command to select the module.
Monitor Mode on an HP 1301 Mainframe Display: The
following three examples show the types of display you will get:
Chan: _ No channels closed on this card.
Chan: 12 Channel 12 closed.
Chan: 9,1 4-wire ohms set-up with voltage on
channel 9.
*RST Condition: DISPlay:MONitor[:STATe] OFF | 0
Example Enabling the Monitor Mode
DISP:MON:CARD 2 Selects module #2 in a switchbox.
DISP:MON 1 Turns the monitor mode on.
Chapter 5 HP E1351A/53A 16-Channel FET Multiplexer Command Reference 59