Lincoln Electric SVM188-A Welder User Manual


 
INSTALLATION
A-8 A-8
DC-600
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
OUTPUT CONNECTIONS
See Table A.1 for recommended DC-600 cable sizes for combined lengths of electrode and work cables.
TABLE A.1
DC-600 Cable Sizes for Combined Lengths of Copper Electrode and Work Cable
at 100% Duty Cycle
ELECTRODE, WORK AND #21 LEAD
Cable SizeParallel CablesCable Length
1/0 (53mm
2
)2
2
2
Lengths up to 150 ft. (46m)
2/0 (67mm
2
)150 ft.(46m) to 200 ft (61m)
3/0 (85mm
2
)200 ft.(61m) to 250 ft.(76m)
CONNECTIONS
A. Connect Electrode and Work Leads to
Output Terminals.
1. Set the ON/OFF toggle switch to OFF.
2. Locate the retractable strain relief loops directly
below the output terminals in the lower right and
lower left corners of the Case Front Assembly. See
Figure A.9.
3. Pull out the retractable strain relief loops.
4. Insert the electrode lead through the loop directly
below the desired polarity (positive or negative).
Pull through enough cable to reach the output
terminals.
5. Connect electrode lead to the desired terminal
(positive/negative).
6. Tighten the output terminal nut with a wrench.
7. Connect the work lead to the other output
terminal following steps 4-6.
FIGURE A.9 - Output Terminals.
B. Connect #21 Work Sense Lead to Proper
Terminal
There are two work sense lead connection points (+21
and -21) on terminal strip (T.S.2) located behind the
hinged access panel on the right side of the case front.
See 14 Pin MS Type Receptacle section or Terminal
Strip Section for connection procedure.