Lincoln Electric SVM188-A Welder User Manual


 
This is the typical DC open circuit
voltage waveform generated from a
properly operating machine. Note
that each vertical division represents
50 volts and that each horizontal divi-
sion represents 2 milliseconds in
time.
Note: Scope probes connected at
machine output terminals: (+) probe
to positive terminal, (-) probe to nega-
tive high inductance terminal.
SCOPE SETTINGS
Volts/Div.....................50V/Div.
Horizontal Sweep .....2 ms/Div.
Coupling.............................DC
Trigger .........................Internal
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM
CONSTANT CURRENT MODE NO LOAD
0 volts
2ms50V
TROUBLESHOOTING AND REPAIR
F-32 F-32
DC-600
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC