Lincoln Electric SVM188-A Welder User Manual


 
This is the typical DC open circuit
voltage waveform. The machine was
in an open circuit condition (no load)
and operating properly. Note that
each vertical division represents 2
volts and that each horizontal division
represents 5 milliseconds in time.
Note: Scope probes connected at
SCR gate and cathode: (+) probe to
gate, (-) probe to cathode.
SCOPE SETTINGS
Volts/Div.......................2V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger .........................Internal
TYPICAL SCR GATE VOLTAGE WAVEFORM
CONSTANT VOLTAGE INNERSHIELD
MAXIMUM OUTPUT SETTING NO LOAD
0 volts
5ms
2V
TROUBLESHOOTING AND REPAIR
F-36 F-36
DC-600
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC