Lincoln Electric SVM188-A Welder User Manual


 
This is the typical DC open circuit
voltage waveform generated from a
properly operating machine. Note
that each vertical division represents
20 volts and that each horizontal divi-
sion represents 2 milliseconds in
time.
Note: Scope probes connected at
machine output terminals: (+) probe
to positive terminal, (-) probe to nega-
tive high inductance terminal.
SCOPE SETTINGS
Volts/Div.....................20V/Div.
Horizontal Sweep .....2 ms/Div.
Coupling.............................DC
Trigger .........................Internal
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM
CONSTANT VOLTAGE INNERSHIELD
MINIMUM OUTPUT SETTING NO LOAD
0volts
2ms20V
TROUBLESHOOTING AND REPAIR
F-34 F-34