Lincoln Electric SVM188-A Welder User Manual


 
ACCESSORIES
C-4 C-4
DC-600
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
12. Connect stick or air/carbon arc electrode and work
cable. See Figure C.2.
Insert the electrode and work cables through the
strain relief loop on the right side (facing the front
of the machine) of the DC-600.
Connect the electrode cable to the "Positive" ter-
minal on the right side of the MULTI-PROCESS
SWITCH.
Connect the work cable to the "Negative" terminal
on the right side of the MULTI-PROCESS
SWITCH.
NOTE: The instructions above are for connecting
the stick polarity positive. To change the polarity,
turn the DC-600 OFF, and reverse the cables.
NOTE: When it is not necessary to have separate
ground cables for stick and semi-automatic or
automatic welding, connect a jumper from the
MULTI-PROCESS SWITCH "Work" terminal to the
MULTI-PROCESS SWITCH "negative" terminal.
See Figure C.2.
To operate the MULTI-PROCESS SWITCH, refer to the
operating instructions on the switch nameplate.
CONNECTIONS FOR SEMI-AUTO-
MATIC OR AUTOMATIC WIRE FEED-
ER CONTROL
1. Set the DC-600 ON/OFF switch to OFF.
2. Set the DC-600 LOCAL/REMOTE switch to
REMOTE.
3. Set the DC-600 OUTPUT TERMINALS switch to
REMOTE.
4. Set the DC-600 MODE switch to the welding
process being used.
5. Refer to the proper connection diagram in the DIA-
GRAMS section for more information.