Lincoln Electric SVM194-A Welder User Manual


 
FUNCTION PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
The engine will not crank when
the start button is pressed.
(Classic® 300D Kubota)
The battery may be
discharged. Check, and if
necessary, charge or replace
the battery.
The battery cables or battery
connections may be loose or
corroded. Service the battery
terminals.
Make sure battery is fully
charged and properly
connected per the wiring
diagram. Turn on the
run/stop switch, and within 30
seconds, press the start
button while checking for
positive battery voltage where
the lead #62 connects to the
starter solenoid.
If voltage is present when the
start button is pressed, check
that the engine block is
properly connected to the
negative battery terminal. If
the engine block is properly
connected, the
starter/solenoid is defective
and should be serviced or
replaced.
If no voltage is present:
Check the wiring connecting
the starter solenoid, ammeter,
start relay, and start button.
See wiring diagram.
Check the start button.
Check for battery voltage at
the start relay coil, between
leads #212C(+) and lead
#55(-) within 30 seconds of
turning on the run/stop switch
and while pressing the start
button.
If voltage is present, replace
the start relay.
If voltage is not present,
check the #55 lead, all the
conductors and devices
between the #212C lead and
the positive battery terminal.
TROUBLESHOOTING AND REPAIR
F-12 F-12
CLASSIC® 300D & 300G
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC