Lincoln Electric SVM194-A Welder User Manual


 
ALTERNATOR STATOR REMOVAL AND REPLACEMENT (continued)
TROUBLESHOOTING AND REPAIR
F-72 F-72
CLASSIC® 300D & 300G
13. Clear the leads in preparation for remov-
ing the stator/end bracket.
14. Lift the eight brushes from the commuta-
tor. Note the position of the brushes for
reassembly.
ALTERNATOR STATOR REMOVAL
AND REPLACEMENT (continued)
FIGURE F.10 - GENERATOR BRUSH HOLDER CABLE REMOVAL
GENERNATOR
BRUSH HOLDER/COIL
CABLES (4)
15. With the 1/2" wrench, disconnect and
clear the four heavy cables from the gen-
erator brush holders to the coils in the
generator frame. It is not necessary to
remove the brush holder jumper cables.
See Figure F.10. Label leads and posi-
tions for re-assembly.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC