Lincoln Electric SVM194-A Welder User Manual


 
INSTALLATION
A4.2 A4.2
CLASSIC® 300D & 300G
TECHNICAL SPECIFICATIONS - CLASSIC® 300D PERKINS
Make/Model Description Speed (RPM) Displacement Starting Capacities
System
4 Cylinder 135 cu. in
12VDC battery
Fuel: 15 gal.
4 Cycle (2.2 ltrs) (Group 24, 650 57 L.
Perkins Naturally Aspirated High Idle 1800 cold crank amps)
404D-22 Water-Cooled Low Idle 1400 Bore x Stroke
2.0 KW
Starter Oil: 10.30 Qts.
EPA Diesel Engine Full Load 1725 9.75 L.
Tier 4 interim Cast Iron Cylinder, 3.3” x 3.9”
Compliant Block/Crankcase (84mm x 100mm) Coolant: 9.5 Qts.
32.7HP @1800 RPM
9.0 L.
65 A. Alternator
w/ built in reg.
INPUT - DIESEL ENGINE
RATED OUTPUT @ 104°F(40°C) - WELDER
MODEL HEIGHT WIDTH DEPTH WEIGHT
K1643-7 CSA
w/o Wire Feed Module 1354 lbs.
(Code 11472) 45.5 in. 24.00 in. 65.0 in. (616 kg)
(1156 mm) (610 mm) (1651 mm
K1643-8 CSA
w/ Wire Feed Module 1389lbs.
(Codes 11473) (630 kg)
RATED OUTPUT @ 104°F(40°C) - GENERATOR
DESCRIPTION RATED DC OUTPUT * Duty DC CURRENT RANGE
VOLTS @ RATED AMPS CYCLE Fine Adjustments in each Range
40-350 Amps
220-Max.
300 Amp DC Welder 30V @ 250A 100% 160-240
All Copper Windings 32V @ 300A 60% 120-190
Pure DC Power Generator 99V DC Max. OCV @ 1800RPM 80-130
Min.-90
Auxiliary Power
(1)
3,000 Watts Continuous, 60 Hz AC
26 Amps @ 115V
13 Amps @ 230V
PHYSICAL DIMENSIONS
(2)
* Based on a 10 min. period.
(1)
Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to
rated capacity. When welding, available auxiliary power will be reduced.
(2)
Height to top of exhaust elbow.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC