Lincoln Electric SVM194-A Welder User Manual


 
ACCESSORIES
C1.2 C1.2
CLASSIC® 300D & 300G
OPTIONAL FEATURES (Field Installed)
GENERAL OPTIONS
Pipe Thawing with an arc welder can cause fire,
explosion, damage to electric wiring or to the arc
welder if done improperly. The use of an arc welder
for pipe thawing is not approved by the CSA, nor is
it recommended or supported by Lincoln Electric.
------------------------------------------------------------------------
Power Plug Kit (K802D) - A power plug kit for the aux-
iliary power receptacles is available. (Provides a plug
for each receptacle.)
GFCI Receptacle Kit (K1690-1) - Includes one UL
approved 115V ground fault circuit interrupter duplex
type receptacle with cover and installation instructions.
Replaces the factory installed 115V duplex receptacle.
Each receptacle of the GFCI duplex is rated at 20
amps. Maximum total current from the GFCI duplex is
limited to 20 amps. See the MAINTENANCE section
for detailed information on testing and resetting the
GFCI receptacle.
Spark Arrestor Kit (K903-1) - Includes a heavy gage
steel, approved spark arrestor, clamp and adapter for
mounting to the muffler exhaust pipe.
K953-1 TRAILER - Two-wheeled trailer with optional fender
and light package. For highway use, consult applicable feder-
al, state, and local laws regarding possible additional require-
ments. There is a choice of 2 hitches, a fender & a light pack-
age.
K953-1 Trailer
K958-1 Ball Hitch
K958-2 Lunette Eye Hitch
K959-1 Fender & Light Kit
K965-1 Cable Rack
OIL DRAIN KIT K1586-1 - Includes ball valve, hose
and clamp.
STICK OPTIONS
K704 ACCESSORY SET - Includes 35 feet (10 m) of
electrode cable and 30 feet (9 m) of work cable, head-
shield, work clamp and electrode holder. Cable is rated
at 500 amps, 60% duty cycle.
Remote Control Kit (K924-4) - Contains switch,
receptacle, remote control rheostat, and 100 ft (30.5m)
cable for adjusting the OCV at the welding site.(For
Codes below 10911.)
Remote Control Kit (K924-5) - Contains remote con-
trol rheostat and 100 ft. (30.5 m) cable for adjusting
the OCV at the welding site. (For Codes 10911 and
above.)
Remote Control Kit (K2464-1) - Contains remote
control rheostat (for adjusting the CC “STICK OVC),
remote control potentiometer (for adjusting the CV
“WIRE” OCV) and 100 ft. (30.5 m) cable.
TIG OPTIONS
TIG Module (K930-2) - Provides high frequency and
shielding gas control for AC and DC GTAW (TIG) weld-
ing applications. Its compact case is designed for easy
carrying, complete with a handle. High frequency
bypass is built in.The K938-1 Contactor Kit must be
field installed in the TIG Module when used with a ZR-
10. Additionally, the K936-3 control cable is required if
remote control is used. If remote control is not used the
K936-4 control cable is required.
PTA-26V TIG Torch K1783-9-Air cooled 200 amptorch
equipped with valve for gas flow control. 25Ft. length.
Magnum Parts Kit For PTA-26V TIG Torch KP509
Remote Control Cable (K936-4) - Control cable for
connecting the K930-2 TIG Module to a ZR-10 not
equipped with a K892-1 Remote Kit. 9-Socket to a
grounded 115 V plug and a 6 pin MS-connector.
(Contains circuits 31, 32, and ground)
Arc Start Switch K814
Contactor Kit K938-1
Control Cable Extension K937-45-Cable is 45Ft. in
length.
Water Valve Kit K844-1-For use with a water-cooled
TIG torch. Installs inside TIG Module.
WARNING
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC