Bosch Power Tools GCM12SD Saw User Manual


 

$%# !
Brake does not stop blade in about
5
seconds.
Motor does not start.
Flash of light from motor endcap
when switch is released.
(&
1. Brushes not seated or lightly
s
ticking or worn.
2. Motor overheated from use
of dull blade/too heavy of a
blade, not recommended
accessory or rapid on/off
cycling.
3. Blade bolt loose.
4. Other.
1. Check that unit is plugged in.
2. Power source fuse or
time delay fuse.
3. Brushes worn.
4. Other.
Normal - brake working properly.
#%%')'#"
- Inspect/clean or replace
b
rushes (see Maintenance
and Lubrication section).
- Use sharp blade.
- Use a recommended blade.
- Let saw cool down.
- Tighten blade bolt.
- Authorized service.
- Plug unit in. Use different
outlet.
- 15-Amp time delay fuse or
circuit breaker.
- See Motor Brush Replacement in
the Maintenance and Lubrication
section.
- Authorized service.
Troubleshooting
'?<B/92@5<<A6;4B612920A?60.9