Graco 332564B Paint Sprayer User Manual


 
Setup M ode Scree
ns
System Screen
1
System screen 1 includes the following fields which
define your system.
Figure 28 System Screen 1, During Standby
Diagnostic Mode
Select this box to display flow rate and pressure for
eachpumpontheHome Screen, page 58.
Color Pumps
Enter the number of color pumps in your system.
Catalyst Pumps
Enter the number of catalyst pumps in your system.
Non-Mix Pressure
Enter a lower pressure for use when not mixing and
spraying (for example during fill or flushing).
NOTE: Low
pressure systems may be set 100 psi
(0.7 MPa,
7 bar) lower than target pressure; high
pressur
e systems may be set 300 psi (2.1 MPa, 21
bar) low
er than target pressure.
Solvent
Meter
Select t
his box if your system uses a solvent meter.
The Sol
vent K-Factor field will then become active.
Solven
tK-Factor
Enter
the solvent meter K-Factor.
332564B 67