Setup M ode Scree
ns
Flush Screen
Figure 35 Flush Screen
Flush Number
Enter the desired flush sequence (1-5). For hard
to flush colors, select a longer sequence. 1 is the
default, and should be designated for the longest,
most thorough flush duration.
Gun Purge Time
Enter the spray device purge time (0 to 999 seconds).
Initial Flush
Enter the init
ialflushvolume(0to9999cc).
Final Flush
Enter the fina
l flush volume (0 to 9999 cc).
Wash Cycles
AWashCycle
activates the pump with the valves
closed, to u
se pumping motion to thoroughly clean
the pump. E
nter the desired number of wash cycles
(0 to 99). E
ntering a number will make the Strokes
per Cycle fi
eld active.
Strokes p
er Wash Cycle
Enter the
desired pump strokes per wash cycle (0
to 99). De
fault is 1.
332564B 73