Graco 332564B Paint Sprayer User Manual


 
Setup M ode Scree
ns
Calibration S
creens
Calibrate Screen 1
Calibrate Screen 1 initiates a pump pressure check
(stall test) for the selected pump. During the test, the
Stall Test screen will appear.
The pump and l
ines must be primed with color
or catalyst
before doing the stall test. See
System Scre
en 2, page 68 to set test parameters.
See Pump Pre
ssure Check, page 84 for complete
test instru
ctions.
To initiat
e the test, press the Pressure Check
button for
the desired pump. The pump will build
pressure
in the line to a minimum of the Stall Test
Pressure
. The pump will then move to the center
stroke po
sition and stall test the upstroke, followed
by the dow
nstroke.
NOTE: TheLastPassedlogcanonlyberesetby
successfully completing the test.
The screen displays the number of days since the
last stall test was passed for each pump.
Figure 41 Calibrate Screen 1
Figur
e 42 Stall Test Screen
332564B
77