Setup Mode Scree
ns
Pump Screen 3
Pump screen 3 sets the pressure alarm limits for the
pump.
When Inlet Pr
essure in Pump Screen 1, page 74 is
set to Disabl
ed, the inlet limit fields are grayed
out and only t
he outlet limit fields are active. See
Pressure Ala
rm and Deviation Limits, page 76.
Figure 39 Pump Screen 3, Pressure Monitoring
Disabled
When Inlet Pressure in Pump Screen 1, page 74 is
set to Monitor, all fields are active. See
Pressure Alarm and Deviation Limits, page 76.
Figure 40 Pump Screen 3, Pressure Monitoring
Enabled
Pressure Alarm and Deviation Limits
Inlet fields are only active if Inlet Pressure
in Pump Screen 1, page 74 is set to Monitor; they
are grayed out if set to Disabled. Outlet fields are
active at all times.
• Alarm and Deviation ranges are 0-300 psi for
low pressure systems, and 0-1500 psi for high
pressure systems.
• Setting to 0 will disable the alarm. The Inlet Alarm
High and Outlet Alarm High cannot be disabled.
• Alarms and Deviations will display when the inlet
or outlet pressure drops below the low limit or
exceeds the high limit.
76 332564B