RETEST AFTER REPAIR
Retest a machine:
• If it is rejected under test for any reason that requires you to remove any mechanical part
which could affect the machine’s electrical characteristics.
OR
• If you repair or replace any electrical components.
NOTE: 50 Hz machines may be tested using 60 Hz power.
INPUT AMPS AT RATED MACHINE OUTPUT
Input Volts/Hertz Load Amps
208/60 110
230/60 100
460/60 50
575/60 40
200/50 115
220/50 104
380/50 61
440/50 52
INPUT IDLE AMPS
Input Volts/Hertz Maximum Idle Amps
230/60 62
220/50 50
NOTE: Power factor correction capacitors are standard on all models. The capacitors
cause high idle currents, but idle power is low.
OPEN CIRCUIT VOLTAGES
Stick Mode OCV AC 60-70
DC 60-70
TIG Mode OCV AC 60-70
DC 60-70
TROUBLESHOOTING & REPAIR
F-84 F-84
SQUARE WAVE TIG 355