Lincoln Electric SVM118-A Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
F-85 F-85
SQUARE WAVE TIG 355
RETEST AFTER REPAIR (continued)
OUTPUT CURRENT RANGE
2 - 400 Amps AC and DC
RECOMMENDED METERS FOR MACHINE OUTPUT TESTS
VOLTMETER: AC and DC True RMS Meter – Fluke 8922A or equivalent
AMMETER: Columbia Type AX AC or DC Tong Ammeter
IMPORTANT: IF OTHER TYPE METERS ARE USED RESULTS MAY NOT BE ACCURATE
MAIN TRANSFORMER SECONDARY VOLTAGES (SEE FIGURE F32)
Test Points Voltages
X1 to X2 84 to 89VAC
X3 to X4 117 to 125VAC
X5 to X6 22 to 24VAC
X2 to X7 77 to 81VAC
FIGURE F32. – TRANSFORMER LEAD TEST POINTS
X1
X7
X3
X4
X5
X6
X2