OPERATION
B-5 B-5
INVERTEC® V450-PRO
8A. WELD MODE SELECT-FOR
MACHINES EQUIPPED WITH OPTIONAL
ADVANCED PROCESS PANEL
(See Figure B.2 UPPER AND MIDDLE SECTION)
See (WELD MODE DETAILS) in this section.
To program welding modes, the SELECT knob is used
to Scroll through all welding modes. The MEMORY
button is used to store and access welding modes into
locations M1 thru M8.
Modes:
In addition to the 5 welding modes described in SEC-
TION 7, the Advance Process Panel allows you to
select the Following additional modes.
Constant Power mode
In the Power Mode;
The work point will be in the Volts window. The Amp
window will have CP displayed indicating Constant
Power. Once current starts flowing and during the 5
second “Hold” feature the displays will show Volts
and Amps respectively.
Gouge Mode
The gouging mode is specifically designed for car-
bon arc gouging with electrodes up to 3/8”.
Pulsed Modes
In Pulse Modes;
The work point will be in the Amps window and
should be set close to the wire feed speed of the
wire feeder in inches per minute. The Volts window
will have SPd displayed indicating Wire Feed
Speed. Once current starts flowing and during the 5
second “Hold” feature the displays will show amps
and volts.
Pulse Mode features that are displayed while selecting
a Welding pulse mode are listed below:
Steel - .030”, .035”, .045”, .052”, 1/16” – Argon Blends
Stainless Steel - .030”, .035”, .045” – Argon Blends &
Helium/Argon Blends
Aluminum - .035”, 3/64”, 1/16” – 4043 & 5356
Metal Core - .045”, .052”, 1/16” – Argon Blends
Nickel - .035”, .045” – Argon/Helium blends
OUTPUT KNOBOUTPUT KNOB
REMOTEREMOTE
ONON
REMOTEREMOTE
LOCALLOCAL
WELD TERMINALSWELD TERMINALS
CONTROLCONTROL
SELECTSELECT
SELECTSELECT
MPSMPS
AA
OLTSOLTS
VV
ADVANCE PROCESS PANEL- MIDDLE SECTION OF WELDER (OPTIONAL)
MEMORYMEMORY
MEMORY BUTTON MEMORY BUTTON
(M1 THRU M8)(M1 THRU M8)
SELECT BUTTONSELECT BUTTON
(HOT START OR ARC CONTROL)(HOT START OR ARC CONTROL)
ADJUST KNOB ADJUST KNOB
(0 THRU +10 HOT START) (0 THRU +10 HOT START)
(-10 THRU 0 AND 0 THRU +10 ARC CONTROL)(-10 THRU 0 AND 0 THRU +10 ARC CONTROL)
SELECT KNOB SELECT KNOB
(SCOLLS WELDING PROCESSES)(SCOLLS WELDING PROCESSES)
SELECTSELECT
ADJUST ADJUST
SELECTSELECT
OUTPUT KNOBOUTPUT KNOB
REMOTEREMOTE
ONON
REMOTEREMOTE
LOCALLOCAL
WELD TERMINALSWELD TERMINALS
CONTROLCONTROL
SELECTSELECT
SELECTSELECT
MPSMPS
AA
OLTSOLTS
VV
ADVANCE PROCESS PANEL- MIDDLE SECTION OF WELDER (OPTIONAL)
MEMORYMEMORY
MEMORY BUTTON MEMORY BUTTON
(M1 THRU M8)(M1 THRU M8)
SELECT BUTTONSELECT BUTTON
(HOT START OR ARC CONTROL)(HOT START OR ARC CONTROL)
ADJUST KNOB ADJUST KNOB
(0 THRU +10 HOT START) (0 THRU +10 HOT START)
(-10 THRU 0 AND 0 THRU +10 ARC CONTROL)(-10 THRU 0 AND 0 THRU +10 ARC CONTROL)
SELECT KNOB SELECT KNOB
(SCOLLS WELDING PROCESSES)(SCOLLS WELDING PROCESSES)
SELECTSELECT
ADJUST ADJUST
SELECTSELECT
FIGURE B.2
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC