Lincoln Electric SVM199-A Welder User Manual


 
TABLE F.3
AUXILIARY TRANSFORMER NO. 1 TEST (continued)
TROUBLESHOOTING AND REPAIR
F-37 F-37
INVERTEC® V450-PRO
NORMAL EXPECTED
LEAD IDENTIFICATION VOLTAGE
X8 to 41B 28 VAC
X3 to X5 115 VAC
X3 to X4 24 VAC
X6 to X7 24 VAC
X6 to X9 42 VAC
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC