Lincoln Electric SVM199-A Welder User Manual


 
Observe Safety Guidelines detailed in the beginning of this manual.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
TROUBLESHOOTING AND REPAIR
F-10 F-10
INVERTEC® V450-PRO
Fault Codes
Code Description Corrective Action
31 Primary over current. If condition persists The machine needs to
contact an authorized be turned off and back
Lincoln Field Service
on to reset the machine.
Shop
32 CAP bank A under voltage. Check input power Self-clearing as
33 CAP bank B under voltage. reconnect to make sure condition ceases.
34 CAP bank A over voltage. the machine
35 CAP bank B over voltage. is connected for the input
37 Soft start Failed. power being supplied. Cycle power.
39 Glitch on the primary over Check the machine Self-clearing as
current fault interrupt; possibly ground. condition ceases.
caused by noise or a signal level If problem persists
(misc. hardware fault #1) contact an authorized
Lincoln Field Service
Shop
43 CAP delta; CAP A and B are out Check input power
of balance. reconnect to make sure
the machine is
connected for the input
power being supplied.
44 Main CPU problem. The DSP Check the machine
has detected a problem with the ground.
CPU.
47 Possible erroneous electrical If problem persists
noise on Voltage/Frequence contact an authorized
capacitor feed back circuit. Lincoln Field Service
Shop
(misc. hardware fault #2)
48 The main contactor opened If condition persist Self-clearing
unexpectedly. (misc. hardware contact an authorized
fault #3) Lincoln Field Service
Shop
"bad The selected weld mode does If condition persists Press the Mode
node’ not exist in the weld table that is contact an authorized Select button to
“####”
presently loaded in the machine. Lincoln Field Service select a different
Shop mode
STATUS LIGHTS ARE LED’S 9 AND 10 ON CENTER TOP OF CONTROL BOARD