Q-Logic ISR6250 Router User Manual


 
C – Log Messages
C-26 SN0051103-00 A
S
152143 sysTempMon: Setting the fan speed to nor-
mal
User Info The fan(s) speed has been set to normal.
152144 sysTempMon: Temperature back to safe
value. Front: %dC Rear: %dC CPU1: %dC
CPU2: %dC
User Info The router temperature has returned to normal oper-
ating range, Front: %dC Rear: %dC CPU1: %dC
CPU2: %dC
152145 sysTempMon: Critical Temperature, Shut-
ting Down Front: %dC Rear: %dC CPU1: %dC
CPU2: %dC
User Info The router has reached a critical temperature ad is
shutting down, Front: %dC Rear: %dC CPU1: %dC
CPU2: %dC
200721 QL3022:ql3xxx_probe: Adapter eth#%d,
Invalid NVRAM parameters
TOE Fatal A GE port (eth#%d) has invalid NVRAM parameters.
233473 "memory monitor: Detected Uncorrectable
Ecc %08lx system is rebooting in 5 secs\n"
System Fatal Uncorrectable memory error detected at address pro-
vided in log message.
233474 "Failed to register interrupt handler!\n" System Fatal Attempt to register the interrupt handler failed.
233475 "%s class_simple_create failed\n" System Fatal Failed class_simple_create system call from
memory monitor initialization routine.
237572 "Failed to kill sys killer %d\n" System Error Failed to kill system task.
237573 Temperature over high threshold %d System Error The router temperature has exceeded the high tem-
perature threshold.
249862 Temperature is back to normal range %d System Info The router temperature has returned to the normal
operating range.
Table C-1. All iSR6250 Router Log Messages (Continued)
ID Log Message
Module
Type
Msg.
Type
Description