Q-Logic ISR6250 Router User Manual


 
Configuration
Configuring FC Array Hosts and LUN Assignments with the iSR6250
4-10 SN0051103-00 A
S
Configuring FC Array Hosts and LUN
Assignments with the iSR6250
When configuring FC array hosts, you must treat each iSR6250 virtual port group
(VPG) as its own unique FC host within the virtualized storage array. This means if
you have only one VPG enabled, the iSR6250 will have only one host entity. If you
enable two more VPGs,
the iSR6250 will present three separate host entities to your
storage array.
When using the iSR6250 in a high availability configuration, assign each VPG
from the second
iSR6250 blade in the same chassis to the same host entity as
VPG from blade 1.
Figure 4-6 Correct VPG Assignments for High Availability Configuration
Do not put VPG ports in Host entities with other FC hosts.