Tektronix TDS510A Caulking Gun User Manual


 
Command Descriptions
TDS Family Oscilloscope Programmer Manual
2–315
TRIGGER:MAIN:PULSE:SLEWRATE:THRESHOLD:BOTH TTL
sets the trigger threshold to TTL.
TRIGger:MAIn:PULse:SLEWRate:THReshold:HIGH
TDS 500C, 600B, & 700C Only
Sets or queries the upper (most positive) limit of the two threshold levels that a
pulse edge must traverse for the slew rate trigger to occur. This command is
equivalent to setting the higher threshold in the Pulse Slew Rate Trigger’s
Thresholds side menu item.
Trigger
TRIGger:MAIn:PULse:SLEWRate:THReshold:HIGH <NR3>
TRIGger:MAIn:PULse:SLEWRate:THReshold:HIGH?
TRIGger
:
:
PULse
MAIn
:
:
?
<Space>
<NR3>
HIGH
THReshold
SLEWRate
<NR3> is the threshold, in volts.
TRIGGER:MAIN:PULSE:SLEWRATE:THRESHOLD:HIGH 120E-3
sets the upper limit of the pulse slew rate trigger to 120 mV.
TRIGger:MAIn:PULse:SLEWRate:THReshold:LOW
TDS 500C, 600B, & 700C Only
Sets or queries the lower (most negative) limit of the two threshold levels that a
pulse edge must traverse for the slew rate trigger to occur. This command is
equivalent to setting the lower threshold in the Pulse Slew Rate Trigger’s
Thresholds side menu item.
Trigger
TRIGger:MAIn:PULse:SLEWRate:THReshold:LOW <NR3>
Examples
Group
Syntax
Arguments
Examples
Group
Syntax