Prosine 2.5/3.0 Installation & Operation Guide 93
Appendix C: Troubleshooting
206 AC Output voltage too high 1. Some loads, like motors,
can feed power back into
the output of the Prosine.
This may result in a tempo-
rary over-voltage which
may trigger a fault condi-
tion.
2. There is an internal hard-
ware or software fault.
1. Try resetting the unit and
running the load again.
Contact Xantrex if you
find consistent incompati-
bility with a certain type of
load.
2. Record the error code
and contact Xantrex.
207 Internal DC Bus voltage is
low in invert mode.
1. Temporary condition
caused by low battery volt-
age in conjunction with an
overload condition.
2. Internal Fault.
1. Check if battery is OK
(see error code 002). Dis-
connect AC and DC
power to the Prosine.
Reconnect DC and AC
power after 15 minutes. If
the problem persists, con-
tact Xantrex.
2. Record the error code
and contact Xantrex.
Error
Code
Description of Fault Possible Cause Solution