Prosine 2.5/3.0 Installation & Operation Guide 27
Section 3: Configuration
SWITCH BANK 2 (SW2)
Audible Alarm
Switch 1
❃UP Audible signals enabled
Max AC Current Draw
DOWN Audible signals disabled
Switch 2 Not Used
Breaker Rating (Amps)
AC service rating
Maximum DC
Charging Amps
PS 2.5 PS 3.0
Switch 3 Switch
4
12V 24V 12V 24V
❃UP ❃UP 10 A 8 A 55 30 55 30
DOWN UP 15 A 12A 90 45 90 45
UP DOWN 20 A 16A 100 55 100 60
DOWN DOWN 30 A 24A 100 55 120 60
Battery Size
Switch 5, 6, 7, 8 Max DC charging current (amps)
Battery Prosine 2.5 Prosine 3.0
#5 #6 #7 #8 Capacity 12V 24V 12V 24V
❃UP ❃UP ❃UP ❃UP 50 Ah 11A 11A 11A 11A
DOWN UP UP UP 75 Ah 25A 25A 25A 25A
UP DOWN UP UP 100 Ah 33A 33A 33A 33A
DOWN DOWN UP UP 150 Ah 50A 50A 50A 50A
UP UP DOWN UP 200Ah 67A 50A 67A 60A
DOWN UP DOWN UP 300 Ah 100A 50A 100A 60A
UP DOWN DOWN UP 400 Ah 100A 50A 120A 60A
DOWN DOWN DOWN UP 500 Ah 100A 50A 120A 60A
UP UP UP DOWN 600 Ah 100A 50A 120A 60A
DOWN UP UP DOWN 700 Ah 100A 50A 120A 60A
UP DOWN UP DOWN 800 Ah 100A 50A 120A 60A
DOWN DOWN UP DOWN 1000 Ah 100A 50A 120A 60A
UP UP DOWN DOWN 1200 Ah 100A 50A 120A 60A
DOWN UP DOWN DOWN 1400 Ah 100A 50A 120A 60A
UP DOWN DOWN DOWN 1700 Ah 100A 50A 120A 60A
DOWN DOWN DOWN DOWN 2000 Ah
or greater