Prosine 2.5/3.0 Installation & Operation Guide 57
Section 5: Operation
Input Voltage: The Prosine inverter/charger operates from an input voltage ranging from 10 volts to
16 volts, (20 to 32 volts on 24V models) and peak performance occurs when voltage is in the range of
12 volts to 13 volts (24 to 26 volts on 24V models) as shown in the following table.
Prosine Operating Voltage Limits
Operating
Condition
Voltage Range
12-Volt System
Voltage Range
24-Volt System
Normal
10V - 16V 20V - 32V
Peak Performance
12V - 13V 24V - 26V
High Voltage Alarm
LED On
>15.5V >31V
Unit Shuts Down
>16V >32V
Low Voltage Alarm
LED Flashes
≤ 10.5V ≤ 21V
Unit Shuts Down
≤10.0V ≤20V
Unit Restarts
≥12.3V ≥24.6V