Emerson VSSG Air Compressor User Manual


 
3 – 8
VSG/VSSG • Installation, Operation and Maintenance Manual •Vilter/Emerson • 35391SSG
Additional Information
Codes and Standards
Vilter followed the following codes and standards when
designing your foundation:
• ACI
• ASTM
• ASCE 7
• IBC 2006
Operation and Performance
The foundation was designed for:
Outside environment severe exposure
Ambient temperature -10 degrees F to 105 degrees F
Unit weight 20,000 lbs
• RPM 3600
Soil bearing capacity 1,500 lbs/sq.ft.
Wind speed 120 MPH
Exposure factor D
Wind importance factor 1.15
• Concrete poured on and permanently cast against
the earth
General Design Requirements
The compressor foundation is designed to:
Maintain the compressor in alignment and at proper
elevation.
• Minimize vibration and prevents its transmission to
other structures
Provide a permanently rigid support
• Provide suf cient depth to dampen vibrations.
CENTER LINE GAS
COMPRESSION
SYSTEM
10'-0"
5'-0"
OVER ALL G.A. LENGTH + 4'-0"
Figure 3-5. Foundation with Housekeeping Pads Dimensions - Top View
Section 3 • Installation