Ingersoll-Rand 4575759 Impact Driver User Manual


 
8
Sensor I® Expert User Manual
2. Mode Selector Switch
Selects the particular tightening mode: Torque Control, Dynamic Audit,
Yield Control and Angle Control. This switch also allows you to select
the Setup mode to adjust communications parameters, setup and
restore custom modes, and perform diagnostics
3. Reset Button
Used to power up the wrench, reset the wrench before every new
tightening procedure, to set torque and angle values, and to clear
certain fault conditions. When the Reset button is held in, the top
functions on the membrane key pad can be selected.
4. Parameter Adjustment Knob
When the Reset button is held in, this knob adjusts the value of the
parameter being displayed.