26
Sensor I® Expert User Manual
QUALITY CONTROL LIMITS AND STATISTICS
Setup and Viewing Quality Control Limits
1. Press and release the Reset button on the side of the wrench.
2. Move the Mode Selection switch to the tightening mode required.
3. Press the Window key. You will see "--.-" on the display along with "LT"
(low torque limit) flashing in the top left hand corner.
4. Press and hold in the Reset button. The present low torque limit will be
shown.
5. While holding in the Reset button, use the Parameter Adjustment Knob
to adjust the low torque limit to the desired value. Release the Reset
button and press the Window key.
6. To adjust the high torque limit (HT), low angle and high angle limits,
(LA, HA), press the Window key until the desired limit is flashing. Then
hold in the Reset button and adjust as in step 5 above.
7. When all adjustments have been made, press the Window key until all
indicators (LT, HT, LA, HA) have stopped flashing on the display.
8. Press the Reset button until the RUN light appears and commence tight-
ening.
NOTE
In Yield Control, LA and HA must be greater than or equal to 12° for
hard joints, 16° for normal joints, or 24° for soft joints. LT and HT
limits must be greater than the snug torque for all modes.